仪器名称: E8362B PNA 系列网络分析仪,10 MHz 至 20 GHz---徐经理 18912657535 仪器型号: Agilent E8362B PNA 系列网络分析仪 仪器品牌: Agilent 仪器指标: 10 MHz 至 20 GHz

主要特性与技术指标

  • 123 dB动态范围和<0.006 dB迹线噪声
  • <26微秒/点的测量速度,32个通道,16,001点
  • 支持TRL/LRM校准,提供晶圆、夹具、波导和天线测量
  • 混频器转换损耗、回波损耗、隔离和绝对群延迟
  • 放大器增益压缩、谐波、IMD和脉冲射频。

描述

通过可选的软件和/或硬件进行通用网络分析来定制您的应用――例如多端口、脉冲射频等应用。

E8362B 10 MHz - 20 GHz
E8363B 10 MHz - 40 GHz
E8364B 10 MHz - 50 GHz
E8361A 10 MHz - 67 GHz

PNA-L N5230A 300 kHz to 6, 13.5, or 20 GHz
PNA-L N5230A 10 MHz to 20, 40, or 50 GHz
PNA-X N5242A 10 MHz to 26.5 GHz
PNA E8362B 10 MHz to 20 GHz
PNA E8363B 10 MHz to 40 GHz
PNA E8364B 10 MHz to 50 GHz
PNA E8361A 10 MHz to 67 GHz
PNA N5250A 10 MHz to 110 GHz

PNA Network Analyzers1
 E8361A/62B/63B/64B, N5250A 
PNA (highest performance series) PNA (highest performance series)
E836B 10 MHz to 0 GHz E8361A 10 MHz to 67 GHz
E8363B 10 MHz to 40 GHz N550A 10 MHz to 110 GHz
E8364B 10 MHz to 50 GHz
 
Options
To add options to a product, order the corresponding item number.
 Description For E836B For E8363B For E8364B For E8361A For N550A Additional 
 system3 information 
Test set 
 Option 014 • Configurable test set E836B-014 E8363B-014 E8364B-014 E8361A-014 Included
Power configuration 
 Option UNL • Extended power range E836B-UNL E8364B-UNL E8364B-UNL E8361A-UNL Included Only E8361A 
 and bias-tees requires 014
 Option 016 • Add receiver attenuators E836A-016 E8364A-016 E8364A-016 E8361A-016 E8361A-016 Requires UNL 
 (only E8361A also 
 requires 014) 
 Option H85 • High-power configuration E836B-H85 E8363B-H85 E8364B-H85 Contact Contact Includes 014, 016,
 Agilent Agilent UNL*4, 080, 081
Non-linear measurements 
 Option 080 • Frequency offset E836A-080 E8364A-080 E8364A-080 E8361A-080 Included Requires 014
 (E8361A only, 081 
 required if UNL is 
 also purchased) 
 Option 081 • Reference receiver switch E836A-081 E8364A-081 E8364A-081 E8361A-081 Included Requires 014, 080 
 (only E8361A also 
 requires UNL) 
 Option 08 • Scalar-calibrated E836B-08 E8363B-08 E8364B-08 E8361A-08 E8361A-085 Requires 014, 080
 converter measurements 
 Option 083 • Vector- and scalar-calibrated E836A-083 E8364A-083 E8364A-083 E8361A-083 E8361A-0835 Requires 014, 080, 
 converter measurements 081(only E8361A 
 also requires UNL)
 Option 0846 • Embedded LO Measurement E836B-084 E8363B-083 E8364B-083 E8361A-083 Requires Option 083
Pulse, antenna, mm-wave 
 Option H08 • Pulsed-RF measurement E836B-H08 E8363B-H08 E8364B-H08 E8361A-H08 E8361A-H085 Requires 014, 080 
 capability
 Option H11 
 • IF access (for antenna, E836B-H11 E8363B-H11 E8364B-H11 E8361A-H11 Included Requires 014, UNL, 
 pulsed-RF and mm-wave 080, and 081
 measurements) 
Measurement features 
 Option 010 • Time-domain capability E836A-010 E8363A-010 E8364A-010 E8361A-010 E8361A-010 Options 550 and 551 
 Option 550 • 4-port measurement application E836B-550 E8363B-550 E8364B-550 E8361A-550 require 014, and are
 Option 551 • N-port capabilities E836B-551 E8363B-551 E8364B-551 E8361A-551 not compatible with 
 N550A systems 
Accessories 
 Option 1CM • Rack mount kit for use E836A-1CM E8363A-1CM E8364A-1CM E8361A-1CM E8361A-1CM
 without handles 
 Option 1CP • Rack mount kit for use E836A-1CP E8363A-1CP E8364A-1CP E8361A-1CP E8361A-1CP 
 with handles
 N4688A • USB CD R/W drive N4688A N4688A N4688A N4688A N4688A
 N4689A • USB Hub N4689A N4689A N4689A N4689A N4689A
Calibration documentation 
 Option 1A7 • ISO 1705 compliant E836B-1A7 E8363B-1A7 E8364B-1A7 E8361A-1A7 E8361A-1A7
 calibration
 Option UK6 • Commercial calibration E836A-UK6 E8363A-UK6 E8364A-UK6 E8361A-UK6 E8361A-UK6
 certificate with test data 
 Option A6J • ANSI Z540 compliant E836B-A6J E8363B-A6J E8364B-A6J E8361A-A6J E8361A-A6J
 calibration
Note: Item numbers may not correspond to product model number. For example, to order the time-domain option on the E836B, 
the correct item number to order is E836A-010. 
Warranty and service One, and three year warranty service plans are available at time of instrument purchase. 
The N550A 110 GHz system carries a full one-year on-site warranty (where available).
Calibration Three year calibration plans are available at time of instrument purchase.
1. All models are not available in all countries.
. For more detailed information regarding the 110 GHz network analyzer system, refer to the Agilent Web site: www.agilent.com/find/pna 
 and download the N550A Technical Overview, literature number 5988-960EN. 
3. The N550A 110 GHz system also includes an N560A millimeter-wave test set controller, 1.0 mm combiner assembly, interconnecting cables, 
 and installation and productivity assistance. See page 14 for more details.
4. UNL* does not include bias-tees. Only includes source attenuators.
5. Up to 67 GHz.
6. Requires firmware A.07.05 and above plus 1.1 GHz CPU board.